Files
bacnet_stack/ports/atmega168/av.c
T
Kari Argillander cb243c36a8 Improve SPDX identifier coverage (#716)
* Change MIT license texts to SPDX-License-Identifier

SPDX-License-Identifier is much easier to understand and grep than
license text so use that instead.

* Change GPL exception license texts to SPDX-License-Identifier

SPDX-License-Identifier is much easier to understand and grep than
license text so use that instead.

* Change misc license texts to SPDX-License-Identifier

There are some external code in repo which are not licenses as most of
the stuff in this repo. We still want every file to have SPDX identifier
to easily grep licenses.

* Add currently used license files

Even though Bacnet-Stack is using SPDX identifiers we still need to give
those license files with source. For this reason add all license files
to license/ folder.

SPDX has also files which would make same thing but this is style which
example Linux kernel is using and it is quite clear so I choose that one
for now.

I choosed not yet bring CC-PDDC as that is not right license for those
files.

---------

Co-authored-by: Kari Argillander <kari.argillander@fidelix.com>
2024-08-12 15:33:02 -05:00

202 lines
6.8 KiB
C

/**************************************************************************
*
* Copyright (C) 2006 Steve Karg <skarg@users.sourceforge.net>
*
* SPDX-License-Identifier: MIT
*
*********************************************************************/
/* Analog Value Objects - customize for your use */
#include <stdbool.h>
#include <stdint.h>
#include "hardware.h"
#include "bacnet/bacdef.h"
#include "bacnet/bacdcode.h"
#include "bacnet/bacenum.h"
#include "bacnet/bacapp.h"
#include "bacnet/config.h" /* the custom stuff */
#include "bacnet/wp.h"
#include "bacnet/basic/object/av.h"
#ifndef MAX_ANALOG_VALUES
#define MAX_ANALOG_VALUES 10
#endif
#if (MAX_ANALOG_VALUES > 10)
#error Modify the Analog_Value_Name to handle multiple digits
#endif
float AV_Present_Value[MAX_ANALOG_VALUES];
/* we simply have 0-n object instances. Yours might be */
/* more complex, and then you need validate that the */
/* given instance exists */
bool Analog_Value_Valid_Instance(uint32_t object_instance)
{
if (object_instance < MAX_ANALOG_VALUES)
return true;
return false;
}
/* we simply have 0-n object instances. Yours might be */
/* more complex, and then count how many you have */
unsigned Analog_Value_Count(void)
{
return MAX_ANALOG_VALUES;
}
/* we simply have 0-n object instances. Yours might be */
/* more complex, and then you need to return the instance */
/* that correlates to the correct index */
uint32_t Analog_Value_Index_To_Instance(unsigned index)
{
return index;
}
/* we simply have 0-n object instances. Yours might be */
/* more complex, and then you need to return the index */
/* that correlates to the correct instance number */
unsigned Analog_Value_Instance_To_Index(uint32_t object_instance)
{
return object_instance;
}
/* note: the object name must be unique within this device */
char *Analog_Value_Name(uint32_t object_instance)
{
static char text_string[5] = "AV-"; /* okay for single thread */
text_string[3] = '0' + (uint8_t)object_instance;
return text_string;
}
/* return apdu len, or -1 on error */
int Analog_Value_Read_Property(BACNET_READ_PROPERTY_DATA *rpdata)
{
int apdu_len = 0; /* return value */
BACNET_BIT_STRING bit_string;
BACNET_CHARACTER_STRING char_string;
unsigned object_index;
uint8_t *apdu;
apdu = rpdata->application_data;
switch (rpdata->object_property) {
case PROP_OBJECT_IDENTIFIER:
apdu_len = encode_application_object_id(
&apdu[0], OBJECT_ANALOG_VALUE, rpdata->object_instance);
break;
case PROP_OBJECT_NAME:
characterstring_init_ansi(
&char_string, Analog_Value_Name(rpdata->object_instance));
apdu_len =
encode_application_character_string(&apdu[0], &char_string);
break;
case PROP_OBJECT_TYPE:
apdu_len =
encode_application_enumerated(&apdu[0], OBJECT_ANALOG_VALUE);
break;
case PROP_PRESENT_VALUE:
object_index =
Analog_Value_Instance_To_Index(rpdata->object_instance);
apdu_len = encode_application_real(
&apdu[0], AV_Present_Value[object_index]);
break;
case PROP_STATUS_FLAGS:
bitstring_init(&bit_string);
bitstring_set_bit(&bit_string, STATUS_FLAG_IN_ALARM, false);
bitstring_set_bit(&bit_string, STATUS_FLAG_FAULT, false);
bitstring_set_bit(&bit_string, STATUS_FLAG_OVERRIDDEN, false);
bitstring_set_bit(&bit_string, STATUS_FLAG_OUT_OF_SERVICE, false);
apdu_len = encode_application_bitstring(&apdu[0], &bit_string);
break;
case PROP_EVENT_STATE:
apdu_len =
encode_application_enumerated(&apdu[0], EVENT_STATE_NORMAL);
break;
case PROP_OUT_OF_SERVICE:
apdu_len = encode_application_boolean(&apdu[0], false);
break;
case PROP_UNITS:
apdu_len = encode_application_enumerated(&apdu[0], UNITS_PERCENT);
break;
default:
rpdata->error_class = ERROR_CLASS_PROPERTY;
rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
apdu_len = BACNET_STATUS_ERROR;
break;
}
/* only array properties can have array options */
if ((apdu_len >= 0) && (rpdata->array_index != BACNET_ARRAY_ALL)) {
rpdata->error_class = ERROR_CLASS_PROPERTY;
rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
apdu_len = BACNET_STATUS_ERROR;
}
return apdu_len;
}
/* returns true if successful */
bool Analog_Value_Write_Property(BACNET_WRITE_PROPERTY_DATA *wp_data)
{
bool status = false; /* return value */
unsigned int object_index = 0;
int len = 0;
BACNET_APPLICATION_DATA_VALUE value;
if (!Analog_Value_Valid_Instance(wp_data->object_instance)) {
wp_data->error_class = ERROR_CLASS_OBJECT;
wp_data->error_code = ERROR_CODE_UNKNOWN_OBJECT;
return false;
}
/* decode the some of the request */
len = bacapp_decode_application_data(
wp_data->application_data, wp_data->application_data_len, &value);
/* FIXME: len < application_data_len: more data? */
if (len < 0) {
/* error while decoding - a value larger than we can handle */
wp_data->error_class = ERROR_CLASS_PROPERTY;
wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE;
return false;
}
if ((wp_data->object_property != PROP_PRIORITY_ARRAY) &&
(wp_data->array_index != BACNET_ARRAY_ALL)) {
/* only array properties can have array options */
wp_data->error_class = ERROR_CLASS_PROPERTY;
wp_data->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
return false;
}
switch (wp_data->object_property) {
case PROP_PRESENT_VALUE:
if (value.tag == BACNET_APPLICATION_TAG_REAL) {
object_index =
Analog_Value_Instance_To_Index(wp_data->object_instance);
AV_Present_Value[object_index] = value.type.Real;
status = true;
} else {
wp_data->error_class = ERROR_CLASS_PROPERTY;
wp_data->error_code = ERROR_CODE_INVALID_DATA_TYPE;
}
break;
case PROP_OBJECT_IDENTIFIER:
case PROP_OBJECT_NAME:
case PROP_OBJECT_TYPE:
case PROP_STATUS_FLAGS:
case PROP_EVENT_STATE:
case PROP_OUT_OF_SERVICE:
case PROP_DESCRIPTION:
case PROP_PRIORITY_ARRAY:
wp_data->error_class = ERROR_CLASS_PROPERTY;
wp_data->error_code = ERROR_CODE_WRITE_ACCESS_DENIED;
break;
default:
wp_data->error_class = ERROR_CLASS_PROPERTY;
wp_data->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
break;
}
return status;
}