Added more text enumerations from BACnet addenda.
This commit is contained in:
+57
-60
@@ -203,8 +203,14 @@ INDTEXT_DATA bacnet_object_type_names[] = {
|
||||
,
|
||||
{OBJECT_ACCUMULATOR, "Accumulator"}
|
||||
,
|
||||
{OBJECT_PULSE_CONVERTER, "Pulse-Converter"}
|
||||
,
|
||||
{OBJECT_PULSE_CONVERTER, "Pulse-Converter"},
|
||||
|
||||
{OBJECT_EVENT_LOG, "Event-Log"},
|
||||
{OBJECT_GLOBAL_GROUP, "Global-Group"},
|
||||
{OBJECT_TREND_LOG_MULTIPLE, "Trend-Log-Multiple"},
|
||||
{OBJECT_LOAD_CONTROL, "Load-Control"},
|
||||
{OBJECT_STRUCTURED_VIEW, "Structured-View"},
|
||||
|
||||
{0, NULL}
|
||||
/* Enumerated values 0-127 are reserved for definition by ASHRAE.
|
||||
Enumerated values 128-1023 may be used by others subject to
|
||||
@@ -563,64 +569,55 @@ INDTEXT_DATA bacnet_property_names[] = {
|
||||
{PROP_AUTO_SLAVE_DISCOVERY, "auto-slave-discovery"},
|
||||
{PROP_MANUAL_SLAVE_ADDRESS_BINDING, "manual-slave-address-binding"},
|
||||
{PROP_SLAVE_ADDRESS_BINDING, "slave-address-binding"},
|
||||
{PROP_SLAVE_PROXY_ENABLE = 172,
|
||||
PROP_LAST_NOTIFY_TIME = 173,
|
||||
PROP_SCHEDULE_DEFAULT = 174,
|
||||
PROP_ACCEPTED_MODES = 175,
|
||||
PROP_ADJUST_VALUE = 176,
|
||||
PROP_COUNT = 177,
|
||||
PROP_COUNT_BEFORE_CHANGE = 178,
|
||||
PROP_COUNT_CHANGE_TIME = 179,
|
||||
PROP_COV_PERIOD = 180,
|
||||
PROP_INPUT_REFERENCE = 181,
|
||||
PROP_LIMIT_MONITORING_INTERVAL = 182,
|
||||
PROP_LOGGING_DEVICE = 183,
|
||||
PROP_LOGGING_RECORD = 184,
|
||||
PROP_PRESCALE = 185,
|
||||
PROP_PULSE_RATE = 186,
|
||||
PROP_SCALE = 187,
|
||||
PROP_SCALE_FACTOR = 188,
|
||||
PROP_UPDATE_TIME = 189,
|
||||
PROP_VALUE_BEFORE_CHANGE = 190,
|
||||
PROP_VALUE_SET = 191,
|
||||
PROP_VALUE_CHANGE_TIME = 192,
|
||||
/* enumerations 212-225 are used in Addendum e to
|
||||
ANSI/ASHRAE 135-2004 */
|
||||
PROP_ALIGN_INTERVALS = 193,
|
||||
PROP_GROUP_MEMBER_NAMES = 194,
|
||||
PROP_INTERVAL_OFFSET = 195,
|
||||
PROP_LAST_RESTART_REASON = 196,
|
||||
PROP_LOGGING_TYPE = 197,
|
||||
PROP_MEMBER_STATUS_FLAGS = 198,
|
||||
PROP_NOTIFICATION_PERIOD = 199,
|
||||
PROP_PREVIOUS_NOTIFY_RECORD = 200,
|
||||
PROP_REQUESTED_UPDATE_INTERVAL = 201,
|
||||
PROP_RESTART_NOTIFICATION_RECIPIENTS = 202,
|
||||
PROP_TIME_OF_DEVICE_RESTART = 203,
|
||||
PROP_TIME_SYNCHRONIZATION_INTERVAL = 204,
|
||||
PROP_TRIGGER = 205,
|
||||
PROP_UTC_TIME_SYNCHRONIZATION_RECIPIENTS = 206,
|
||||
/* enumerations 207-211 are used in Addendum d to
|
||||
ANSI/ASHRAE 135-2004 */
|
||||
PROP_NODE_SUBTYPE = 207,
|
||||
PROP_NODE_TYPE = 208,
|
||||
PROP_STRUCTURED_OBJECT_LIST = 209,
|
||||
PROP_SUBORDINATE_ANNOTATIONS = 210,
|
||||
PROP_SUBORDINATE_LIST = 211,
|
||||
/* enumerations 212-225 are used in Addendum e to
|
||||
ANSI/ASHRAE 135-2004 */
|
||||
PROP_ACTUAL_SHED_LEVEL = 212,
|
||||
PROP_DUTY_WINDOW = 213,
|
||||
PROP_EXPECTED_SHED_LEVEL = 214,
|
||||
PROP_FULL_DUTY_BASELINE = 215,
|
||||
/* FIXME: is this the right enumeration? */
|
||||
/* PROP_NODE_SUBTYPE = 216, */
|
||||
/* PROP_NODE_TYPE = 217, */
|
||||
PROP_REQUESTED_SHED_LEVEL = 218,
|
||||
PROP_SHED_DURATION = 219,
|
||||
PROP_SHED_LEVEL_DESCRIPTIONS = 220,
|
||||
PROP_SHED_LEVELS = 221,
|
||||
PROP_STATE_DESCRIPTION = 222,
|
||||
{PROP_SLAVE_PROXY_ENABLE, "slave-proxy-enable"},
|
||||
{PROP_LAST_NOTIFY_TIME, "last-notify-time"},
|
||||
{PROP_SCHEDULE_DEFAULT, "schedule-default"},
|
||||
{PROP_ACCEPTED_MODES, "accepted-modes"},
|
||||
{PROP_ADJUST_VALUE, "adjust-value"},
|
||||
{PROP_COUNT, "count"},
|
||||
{PROP_COUNT_BEFORE_CHANGE, "count-before-change"},
|
||||
{PROP_COUNT_CHANGE_TIME, "count-change-time"},
|
||||
{PROP_COV_PERIOD, "COV-period"},
|
||||
{PROP_INPUT_REFERENCE, "input-reference"},
|
||||
{PROP_LIMIT_MONITORING_INTERVAL, "limit-monitoring-interval"},
|
||||
{PROP_LOGGING_DEVICE, "logging-device"},
|
||||
{PROP_LOGGING_RECORD, "logging-record"},
|
||||
{PROP_PRESCALE, "prescale"},
|
||||
{PROP_PULSE_RATE, "pulse-rate"},
|
||||
{PROP_SCALE, "scale"},
|
||||
{PROP_SCALE_FACTOR, "scale-factor"},
|
||||
{PROP_UPDATE_TIME, "update-time"},
|
||||
{PROP_VALUE_BEFORE_CHANGE, "value-before-change"},
|
||||
{PROP_VALUE_SET, "value-set"},
|
||||
{PROP_VALUE_CHANGE_TIME, "value-change-time"},
|
||||
{PROP_ALIGN_INTERVALS, "align-intervals"},
|
||||
{PROP_GROUP_MEMBER_NAMES, "group-member-names"},
|
||||
{PROP_INTERVAL_OFFSET, "interval-offset"},
|
||||
{PROP_LAST_RESTART_REASON, "last-restart-reason"},
|
||||
{PROP_LOGGING_TYPE, "logging-type"},
|
||||
{PROP_MEMBER_STATUS_FLAGS, "member-status-flags"},
|
||||
{PROP_NOTIFICATION_PERIOD, "notification-period"},
|
||||
{PROP_PREVIOUS_NOTIFY_RECORD, "previous-notify-record"},
|
||||
{PROP_REQUESTED_UPDATE_INTERVAL, "requested-update-interval"},
|
||||
{PROP_RESTART_NOTIFICATION_RECIPIENTS, "restart-notification-recipients"},
|
||||
{PROP_TIME_OF_DEVICE_RESTART, "time-of-device-restart"},
|
||||
{PROP_TIME_SYNCHRONIZATION_INTERVAL, "time-synchronization-interval"},
|
||||
{PROP_TRIGGER, "trigger"},
|
||||
{PROP_UTC_TIME_SYNCHRONIZATION_RECIPIENTS, "UTC-time-synchronization-recipients"},
|
||||
{PROP_NODE_SUBTYPE, "node-subtype"},
|
||||
{PROP_NODE_TYPE, "node-type"},
|
||||
{PROP_STRUCTURED_OBJECT_LIST, "structured-object-list"},
|
||||
{PROP_SUBORDINATE_ANNOTATIONS, "subordinate-annotations"},
|
||||
{PROP_SUBORDINATE_LIST, "subordinate-list"},
|
||||
{PROP_ACTUAL_SHED_LEVEL, "actual-shed-level"},
|
||||
{PROP_DUTY_WINDOW, "duty-window"},
|
||||
{PROP_EXPECTED_SHED_LEVEL, "expected-shed-level"},
|
||||
{PROP_FULL_DUTY_BASELINE, "full-duty-baseline"},
|
||||
{PROP_REQUESTED_SHED_LEVEL, "requested-shed-level"},
|
||||
{PROP_SHED_DURATION, "shed-duration"},
|
||||
{PROP_SHED_LEVEL_DESCRIPTIONS, "shed-level-descriptions"},
|
||||
{PROP_SHED_LEVELS, "shed-levels"},
|
||||
{PROP_STATE_DESCRIPTION, "state-descriptions"},
|
||||
|
||||
{0, NULL}
|
||||
/* Enumerated values 0-511 are reserved for definition by ASHRAE.
|
||||
|
||||
Reference in New Issue
Block a user