refactored send-read-property to allow the request using a BACnet-Address.

This commit is contained in:
skarg
2012-08-02 20:25:43 +00:00
parent f8d5ad0dfe
commit 2f21b3e352
2 changed files with 98 additions and 54 deletions
+91 -54
View File
@@ -45,6 +45,91 @@
/** @file s_rp.c Send Read Property request. */
/** Sends a Read Property request
* @ingroup DSRP
*
* @param dest [in] BACNET_ADDRESS of the destination device
* @param max_apdu [in]
* @param object_type [in] Type of the object whose property is to be read.
* @param object_instance [in] Instance # of the object to be read.
* @param object_property [in] Property to be read, but not ALL, REQUIRED, or OPTIONAL.
* @param array_index [in] Optional: if the Property is an array,
* - 0 for the array size
* - 1 to n for individual array members
* - BACNET_ARRAY_ALL (~0) for the full array to be read.
* @return invoke id of outgoing message, or 0 if device is not bound or no tsm available
*/
uint8_t Send_Read_Property_Request_Address(
BACNET_ADDRESS *dest,
uint16_t max_apdu,
BACNET_OBJECT_TYPE object_type,
uint32_t object_instance,
BACNET_PROPERTY_ID object_property,
uint32_t array_index)
{
BACNET_ADDRESS my_address;
uint8_t invoke_id = 0;
bool status = false;
int len = 0;
int pdu_len = 0;
int bytes_sent = 0;
BACNET_READ_PROPERTY_DATA data;
BACNET_NPDU_DATA npdu_data;
if (!dcc_communication_enabled()) {
return 0;
}
if (!dest) {
return 0;
}
/* is there a tsm available? */
invoke_id = tsm_next_free_invokeID();
if (invoke_id) {
/* encode the NPDU portion of the packet */
datalink_get_my_address(&my_address);
npdu_encode_npdu_data(&npdu_data, true, MESSAGE_PRIORITY_NORMAL);
pdu_len =
npdu_encode_pdu(&Handler_Transmit_Buffer[0], dest, &my_address,
&npdu_data);
/* encode the APDU portion of the packet */
data.object_type = object_type;
data.object_instance = object_instance;
data.object_property = object_property;
data.array_index = array_index;
len =
rp_encode_apdu(&Handler_Transmit_Buffer[pdu_len], invoke_id,
&data);
pdu_len += len;
/* will it fit in the sender?
note: if there is a bottleneck router in between
us and the destination, we won't know unless
we have a way to check for that and update the
max_apdu in the address binding table. */
if ((uint16_t) pdu_len < max_apdu) {
tsm_set_confirmed_unsegmented_transaction(invoke_id, dest,
&npdu_data, &Handler_Transmit_Buffer[0], (uint16_t) pdu_len);
bytes_sent =
datalink_send_pdu(dest, &npdu_data,
&Handler_Transmit_Buffer[0], pdu_len);
#if PRINT_ENABLED
if (bytes_sent <= 0)
fprintf(stderr, "Failed to Send ReadProperty Request (%s)!\n",
strerror(errno));
#endif
} else {
tsm_free_invoke_id(invoke_id);
invoke_id = 0;
#if PRINT_ENABLED
fprintf(stderr,
"Failed to Send ReadProperty Request "
"(exceeds destination maximum APDU)!\n");
#endif
}
}
return invoke_id;
}
/** Sends a Read Property request.
* @ingroup DSRP
*
@@ -65,66 +150,18 @@ uint8_t Send_Read_Property_Request(
BACNET_PROPERTY_ID object_property,
uint32_t array_index)
{
BACNET_ADDRESS dest;
BACNET_ADDRESS my_address;
BACNET_ADDRESS dest = {0};
unsigned max_apdu = 0;
uint8_t invoke_id = 0;
bool status = false;
int len = 0;
int pdu_len = 0;
int bytes_sent = 0;
BACNET_READ_PROPERTY_DATA data;
BACNET_NPDU_DATA npdu_data;
if (!dcc_communication_enabled())
return 0;
/* is the device bound? */
status = address_get_by_device(device_id, &max_apdu, &dest);
/* is there a tsm available? */
if (status)
invoke_id = tsm_next_free_invokeID();
if (invoke_id) {
/* encode the NPDU portion of the packet */
datalink_get_my_address(&my_address);
npdu_encode_npdu_data(&npdu_data, true, MESSAGE_PRIORITY_NORMAL);
pdu_len =
npdu_encode_pdu(&Handler_Transmit_Buffer[0], &dest, &my_address,
&npdu_data);
/* encode the APDU portion of the packet */
data.object_type = object_type;
data.object_instance = object_instance;
data.object_property = object_property;
data.array_index = array_index;
len =
rp_encode_apdu(&Handler_Transmit_Buffer[pdu_len], invoke_id,
&data);
pdu_len += len;
/* will it fit in the sender?
note: if there is a bottleneck router in between
us and the destination, we won't know unless
we have a way to check for that and update the
max_apdu in the address binding table. */
if ((unsigned) pdu_len < max_apdu) {
tsm_set_confirmed_unsegmented_transaction(invoke_id, &dest,
&npdu_data, &Handler_Transmit_Buffer[0], (uint16_t) pdu_len);
bytes_sent =
datalink_send_pdu(&dest, &npdu_data,
&Handler_Transmit_Buffer[0], pdu_len);
#if PRINT_ENABLED
if (bytes_sent <= 0)
fprintf(stderr, "Failed to Send ReadProperty Request (%s)!\n",
strerror(errno));
#endif
} else {
tsm_free_invoke_id(invoke_id);
invoke_id = 0;
#if PRINT_ENABLED
fprintf(stderr,
"Failed to Send ReadProperty Request "
"(exceeds destination maximum APDU)!\n");
#endif
}
if (status) {
invoke_id = Send_Read_Property_Request_Address(
&dest, max_apdu, object_type,
object_instance, object_property,
array_index);
}
return invoke_id;
+7
View File
@@ -114,6 +114,13 @@ extern "C" {
/* returns the invoke ID for confirmed request, or 0 if failed */
uint8_t Send_Read_Property_Request_Address(
BACNET_ADDRESS *dest,
uint16_t max_apdu,
BACNET_OBJECT_TYPE object_type,
uint32_t object_instance,
BACNET_PROPERTY_ID object_property,
uint32_t array_index);
uint8_t Send_Read_Property_Request(
uint32_t device_id, /* destination device */
BACNET_OBJECT_TYPE object_type,