Files
gateway/components/knx_dali_gw/knxprod/DALI-GW.share.xml
T
Tony c60ef2ccde feat: Enhance DALI Gateway with RGBW and RGBCW support
- Added support for RGBW and RGBCW color modes in the DALI Gateway.
- Updated JSON color mode parsing to handle new color types.
- Extended the StoreDt8SceneSnapshot function to include white, amber, and free color parameters.
- Introduced new methods in DaliGatewayBridge for setting RGBW, RGBCW, and RGBWAF colors.
- Modified KnxDaliChannel to send RGBW and RGBCW colors based on the color type.
- Updated parameter types and definitions in the KNX product XML files to accommodate new color modes.
- Enhanced README with migration details and validation instructions.

Signed-off-by: Tony <tonylu@tony-cloud.com>
2026-05-29 11:32:10 +08:00

54 lines
2.5 KiB
XML

<?xml version="1.0" encoding="utf-8" ?>
<KNX xmlns="http://knx.org/xml/project/20" xmlns:op="http://github.com/OpenKNX/OpenKNXproducer">
<ManufacturerData>
<Manufacturer RefId="M-00FA">
<ApplicationPrograms>
<ApplicationProgram>
<Static>
<ParameterTypes>
<ParameterType Id="%AID%_PT-Bool" Name="Bool">
<TypeRestriction Base="Value" SizeInBit="1">
<Enumeration Id="%AID%_PT-Bool_EN-0" Text="Disabled" Value="0" />
<Enumeration Id="%AID%_PT-Bool_EN-1" Text="Enabled" Value="1" />
</TypeRestriction>
</ParameterType>
<ParameterType Id="%AID%_PT-ColorType" Name="ColorType">
<TypeRestriction Base="Value" SizeInBit="%DALI_ColorTypeBits%">
<Enumeration Id="%AID%_PT-ColorType_EN-0" Text="HSV" Value="0" />
<Enumeration Id="%AID%_PT-ColorType_EN-1" Text="RGB" Value="1" />
<Enumeration Id="%AID%_PT-ColorType_EN-2" Text="Tunable white" Value="2" />
<Enumeration Id="%AID%_PT-ColorType_EN-3" Text="xyY" Value="3" />
<Enumeration Id="%AID%_PT-ColorType_EN-4" Text="RGBW" Value="4" />
<Enumeration Id="%AID%_PT-ColorType_EN-5" Text="RGBCW" Value="5" />
</TypeRestriction>
</ParameterType>
<ParameterType Id="%AID%_PT-Level" Name="Level">
<TypeRestriction Base="Value" SizeInBit="8" />
</ParameterType>
<ParameterType Id="%AID%_PT-Kelvin" Name="Kelvin">
<TypeNumber SizeInBit="16" Type="unsignedInt" minInclusive="1000" maxInclusive="20000" />
</ParameterType>
</ParameterTypes>
<ComObjectTable />
<ComObjectRefs />
<ParameterRefs />
</Static>
<Dynamic>
<ChannelIndependentBlock>
<ParameterBlock Id="%AID%_PB-DALI-Main" Text="DALI Gateway" Inline="true" Layout="Grid">
<Rows>
<Row Id="%AID%_PB-DALI-Main_R-1" />
</Rows>
<Columns>
<Column Id="%AID%_PB-DALI-Main_C-1" Width="100%" />
</Columns>
<ParameterSeparator Id="%AID%_PS-DALI-Main" Text="DALI Gateway" Cell="1,1" />
</ParameterBlock>
</ChannelIndependentBlock>
</Dynamic>
</ApplicationProgram>
</ApplicationPrograms>
</Manufacturer>
</ManufacturerData>
</KNX>