Files
bacnet_stack/test/bacnet/datalink/mock/src/bip6-mock.c
T
Kari Argillander f806c5829b Run clang-format and enable CI check for it (#755)
* pre-commit: Update and enable clang-format check

There is newer version from clang-format so use that. We do not yet want
18 as that is little bit too new.

* Format some thing by hand which clang-format "breaks"

Clang-format will format some things little bit off in some cases.
Format some things by hand so we get cleaner end result.

* Run clang-format with

```
pre-commit run --all-files clang-format
```

We have already in previously checked places where clang-format does not
make good format and ignored those (hopefully most of the things).

---------

Co-authored-by: Kari Argillander <kari.argillander@fidelix.com>
2024-08-30 11:20:58 -05:00

119 lines
2.5 KiB
C

/*
* Copyright (c) 2020 Legrand North America, LLC.
*
* SPDX-License-Identifier: MIT
*/
#include <zephyr/ztest.h>
#include <stdio.h>
#include <stdlib.h>
#include <stdint.h> /* for standard integer types uint8_t etc. */
#include <stdbool.h> /* for the standard bool type. */
#include "bacnet/datalink/bip6.h"
bool bip6_init(char *ifname)
{
ztest_check_expected_value(ifname);
return ztest_get_return_value();
}
void bip6_cleanup(void)
{
}
bool bip6_get_broadcast_addr(BACNET_IP6_ADDRESS *addr)
{
ztest_copy_return_data(addr, sizeof(BACNET_IP6_ADDRESS));
return ztest_get_return_value();
}
void bip6_get_my_address(BACNET_ADDRESS *my_address)
{
ztest_copy_return_data(my_address, sizeof(BACNET_ADDRESS));
}
int bip6_send_pdu(
BACNET_ADDRESS *dest,
BACNET_NPDU_DATA *npdu_data,
uint8_t *pdu,
unsigned pdu_len)
{
ztest_check_expected_value(dest);
ztest_check_expected_value(npdu_data);
ztest_check_expected_data(pdu, pdu_len);
return ztest_get_return_value();
}
uint16_t bip6_receive(
BACNET_ADDRESS *src, uint8_t *pdu, uint16_t max_pdu, unsigned timeout)
{
ztest_check_expected_value(src);
ztest_check_expected_value(timeout);
ztest_copy_return_data(pdu, max_pdu);
return ztest_get_return_value();
}
void bip6_set_interface(char *ifname)
{
ztest_check_expected_value(ifname);
}
bool bip6_address_match_self(const BACNET_IP6_ADDRESS *addr)
{
ztest_check_expected_value(addr);
return ztest_get_return_value();
}
bool bip6_set_addr(const BACNET_IP6_ADDRESS *addr)
{
ztest_check_expected_data(addr, sizeof(BACNET_IP6_ADDRESS));
return ztest_get_return_value();
}
bool bip6_get_addr(BACNET_IP6_ADDRESS *addr)
{
ztest_copy_return_data(addr, sizeof(BACNET_IP6_ADDRESS));
return ztest_get_return_value();
}
void bip6_set_port(uint16_t port)
{
ztest_check_expected_value(port);
}
uint16_t bip6_get_port(void)
{
return ztest_get_return_value();
}
void bip6_get_broadcast_address(BACNET_ADDRESS *my_address)
{
ztest_copy_return_data(my_address, sizeof(BACNET_ADDRESS));
}
bool bip6_set_broadcast_addr(const BACNET_IP6_ADDRESS *addr)
{
return ztest_get_return_value();
}
int bip6_send_mpdu(
const BACNET_IP6_ADDRESS *dest, const uint8_t *mtu, uint16_t mtu_len)
{
ztest_check_expected_value(dest);
ztest_check_expected_data(mtu, mtu_len);
return ztest_get_return_value();
}
bool bip6_send_pdu_queue_empty(void)
{
return ztest_get_return_value();
}
void bip6_receive_callback(void)
{
}
void bip6_debug_enable(void)
{
}