/************************************************************************** * * Copyright (C) 2005 Steve Karg * * Permission is hereby granted, free of charge, to any person obtaining * a copy of this software and associated documentation files (the * "Software"), to deal in the Software without restriction, including * without limitation the rights to use, copy, modify, merge, publish, * distribute, sublicense, and/or sell copies of the Software, and to * permit persons to whom the Software is furnished to do so, subject to * the following conditions: * * The above copyright notice and this permission notice shall be included * in all copies or substantial portions of the Software. * * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. * IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY * CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, * TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE * SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. * *********************************************************************/ #include #include #include #include #include #include "config.h" #include "txbuf.h" #include "bacdef.h" #include "bacdcode.h" #include "bacerror.h" #include "bacdevobjpropref.h" #include "apdu.h" #include "npdu.h" #include "abort.h" #include "rp.h" /* function that handles the reading of properties from objects */ static read_property_function Read_Property_Function; void handler_read_property_function_set( read_property_function pFunction) { Read_Property_Function = pFunction; } void handler_read_property( uint8_t * service_request, uint16_t service_len, BACNET_ADDRESS * src, BACNET_CONFIRMED_SERVICE_DATA * service_data) { BACNET_READ_PROPERTY_DATA rpdata; int len = 0; int pdu_len = 0; int apdu_len = -1; int npdu_len = -1; BACNET_NPDU_DATA npdu_data; bool error = false; int bytes_sent = 0; BACNET_ADDRESS my_address; /* encode the NPDU portion of the packet */ datalink_get_my_address(&my_address); npdu_encode_npdu_data(&npdu_data, false, MESSAGE_PRIORITY_NORMAL); npdu_len = npdu_encode_pdu(&Handler_Transmit_Buffer[0], src, &my_address, &npdu_data); if (service_data->segmented_message) { /* we don't support segmentation - send an abort */ apdu_len = abort_encode_apdu(&Handler_Transmit_Buffer[npdu_len], service_data->invoke_id, ABORT_REASON_SEGMENTATION_NOT_SUPPORTED, true); #if PRINT_ENABLED fprintf(stderr, "RP: Segmented message. Sending Abort!\n"); #endif goto RP_ABORT; } len = rp_decode_service_request(service_request, service_len, &rpdata); #if PRINT_ENABLED if (len <= 0) { fprintf(stderr, "RP: Unable to decode Request!\n"); } #endif if (len < 0) { /* bad decoding - send an abort */ apdu_len = abort_encode_apdu(&Handler_Transmit_Buffer[npdu_len], service_data->invoke_id, ABORT_REASON_OTHER, true); #if PRINT_ENABLED fprintf(stderr, "RP: Bad Encoding. Sending Abort!\n"); #endif goto RP_ABORT; } /* assume that there is an error */ error = true; if (Read_Property_Function) { apdu_len = rp_ack_encode_apdu_init( &Handler_Transmit_Buffer[npdu_len], service_data->invoke_id, &rpdata); /* configure our storage */ rpdata.application_data = &Handler_Transmit_Buffer[npdu_len+apdu_len]; rpdata.application_data_len = sizeof(Handler_Transmit_Buffer) - (npdu_len + apdu_len); len = Read_Property_Function(&rpdata); if (len >= 0) { apdu_len += len; len = rp_ack_encode_apdu_object_property_end( &Handler_Transmit_Buffer[npdu_len+apdu_len]); apdu_len += len; if (apdu_len > service_data->max_resp) { /* too big for the sender - send an abort */ apdu_len = abort_encode_apdu(&Handler_Transmit_Buffer[npdu_len], service_data->invoke_id, ABORT_REASON_SEGMENTATION_NOT_SUPPORTED, true); #if PRINT_ENABLED fprintf(stderr, "RP: Message too large. Sending Abort!\n"); #endif goto RP_ABORT; } else { #if PRINT_ENABLED fprintf(stderr, "RP: Sending Ack!\n"); #endif error = false; } } } if (error) { if (len == -2) { /* BACnet APDU too small to fit data, so proper response is Abort */ apdu_len = abort_encode_apdu(&Handler_Transmit_Buffer[npdu_len], service_data->invoke_id, ABORT_REASON_SEGMENTATION_NOT_SUPPORTED, true); #if PRINT_ENABLED fprintf(stderr, "RP: Reply too big to fit into APDU!\n"); #endif } else { apdu_len = bacerror_encode_apdu(&Handler_Transmit_Buffer[npdu_len], service_data->invoke_id, SERVICE_CONFIRMED_READ_PROPERTY, rpdata.error_class, rpdata.error_code); #if PRINT_ENABLED fprintf(stderr, "RP: Sending Error!\n"); #endif } } RP_ABORT: pdu_len = npdu_len + apdu_len; bytes_sent = datalink_send_pdu(src, &npdu_data, &Handler_Transmit_Buffer[0], pdu_len); #if PRINT_ENABLED if (bytes_sent <= 0) fprintf(stderr, "Failed to send PDU (%s)!\n", strerror(errno)); #endif return; }