/************************************************************************** * * Copyright (C) 2005 Steve Karg * * Permission is hereby granted, free of charge, to any person obtaining * a copy of this software and associated documentation files (the * "Software"), to deal in the Software without restriction, including * without limitation the rights to use, copy, modify, merge, publish, * distribute, sublicense, and/or sell copies of the Software, and to * permit persons to whom the Software is furnished to do so, subject to * the following conditions: * * The above copyright notice and this permission notice shall be included * in all copies or substantial portions of the Software. * * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. * IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY * CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, * TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE * SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. * *********************************************************************/ #include #include #include #include #include #include "config.h" #include "txbuf.h" #include "bacdef.h" #include "bacdcode.h" #include "apdu.h" #include "npdu.h" #include "abort.h" //#include "arf.h" /* demo objects */ #include "device.h" #include "ai.h" #include "ao.h" #if defined(BACFILE) #include "bacfile.h" #endif #include "mydata.h" #include "ptransfer.h" #define MYMAXSTR 32 #define MYMAXBLOCK 8 DATABLOCK MyData[MYMAXBLOCK]; uint8_t IOBufferPT[MAX_APDU]; // Buffer for building response in void ProcessPT(BACNET_PRIVATE_TRANSFER_DATA *data) { int iLen; // Index to current location in data char cBlockNumber; uint32_t ulTemp; int tag_len; uint8_t tag_number; uint32_t len_value_type; BACNET_CHARACTER_STRING bsTemp; iLen = 0; // Decode the block number tag_len = decode_tag_number_and_value(&data->serviceParameters[iLen], &tag_number, &len_value_type); iLen += tag_len; if (tag_number != BACNET_APPLICATION_TAG_UNSIGNED_INT) { // Bail out early if wrong type data->serviceParametersLen = 0; // and signal unexpected error return; } iLen += decode_unsigned(&data->serviceParameters[iLen], len_value_type, &ulTemp); cBlockNumber = (char)ulTemp; if(cBlockNumber < MY_MAX_BLOCK) { if(data->serviceNumber == MY_SVC_READ) { // Read Response is an unsigned int with 0 for success or a non 0 error code // For a successful read the 0 success code is followed by the block number // and then the block contents which consist of 2 unsigned ints (in 0 to 255 // range as they are really chars) a single precision real and a string which // will be up to 32 chars + a nul iLen = 0; iLen += encode_application_unsigned(&IOBufferPT[iLen], MY_ERR_OK); // Signal success iLen += encode_application_unsigned(&IOBufferPT[iLen], cBlockNumber); // Followed by the block number iLen += encode_application_unsigned(&IOBufferPT[iLen], MyData[cBlockNumber].cMyByte1); // And Then the block contents iLen += encode_application_unsigned(&IOBufferPT[iLen], MyData[cBlockNumber].cMyByte2); iLen += encode_application_real(&IOBufferPT[iLen], MyData[cBlockNumber].fMyReal); characterstring_init_ansi(&bsTemp, MyData[cBlockNumber].sMyString); iLen += encode_application_character_string(&IOBufferPT[iLen], &bsTemp); } else { // Write operation // Write block consists of the block number followed by the block contents as // described above for the read operation. The returned result is an unsigned // response which is 0 for success and a non 0 error code otherwise. tag_len = decode_tag_number_and_value(&data->serviceParameters[iLen], &tag_number, &len_value_type); iLen += tag_len; if (tag_number != BACNET_APPLICATION_TAG_UNSIGNED_INT) { data->serviceParametersLen = 0; return; } iLen += decode_unsigned(&data->serviceParameters[iLen], len_value_type, &ulTemp); MyData[cBlockNumber].cMyByte1 = (char)ulTemp; tag_len = decode_tag_number_and_value(&data->serviceParameters[iLen], &tag_number, &len_value_type); iLen += tag_len; if (tag_number != BACNET_APPLICATION_TAG_UNSIGNED_INT) { data->serviceParametersLen = 0; return; } iLen += decode_unsigned(&data->serviceParameters[iLen], len_value_type, &ulTemp); MyData[cBlockNumber].cMyByte2 = (char)ulTemp; tag_len = decode_tag_number_and_value(&data->serviceParameters[iLen], &tag_number, &len_value_type); iLen += tag_len; if (tag_number != BACNET_APPLICATION_TAG_REAL) { data->serviceParametersLen = 0; return; } iLen += decode_real(&data->serviceParameters[iLen], &MyData[cBlockNumber].fMyReal); tag_len = decode_tag_number_and_value(&data->serviceParameters[iLen], &tag_number, &len_value_type); iLen += tag_len; if (tag_number != BACNET_APPLICATION_TAG_CHARACTER_STRING) { data->serviceParametersLen = 0; return; } decode_character_string(&data->serviceParameters[iLen], len_value_type, &bsTemp); strncpy(MyData[cBlockNumber].sMyString, characterstring_value(&bsTemp), MY_MAX_STR); // Only copy as much as we can accept MyData[cBlockNumber].sMyString[MY_MAX_STR] = '\0'; // Make sure it is nul terminated iLen = encode_application_unsigned(&IOBufferPT[0], MY_ERR_OK); // Signal success } } else { iLen = encode_application_unsigned(&IOBufferPT[0], MY_ERR_BAD_INDEX); // Signal bad index } data->serviceParametersLen = iLen; data->serviceParameters = IOBufferPT; } /* * This is called when we receive a private transfer packet. * We parse the data, send the private part for processing and then send the * response which the application generates. * If there are any BACnet level errors we send an error response from here. * If there are any application level errors they will be packeged up in the * response block which we send back to the originator of the request. * */ void handler_conf_private_trans( uint8_t * service_request, uint16_t service_len, BACNET_ADDRESS * src, BACNET_CONFIRMED_SERVICE_DATA * service_data) { BACNET_PRIVATE_TRANSFER_DATA data; int len; int pdu_len; bool error; int bytes_sent; BACNET_NPDU_DATA npdu_data; BACNET_ADDRESS my_address; BACNET_ERROR_CLASS error_class; BACNET_ERROR_CODE error_code; len = 0; pdu_len = 0; error = false; bytes_sent = 0; error_class = ERROR_CLASS_OBJECT; error_code = ERROR_CODE_UNKNOWN_OBJECT; #if PRINT_ENABLED fprintf(stderr,"Received Confirmed Private Transfer Request!\n"); #endif // encode the NPDU portion of the response packet as it will be needed // no matter what the outcome. datalink_get_my_address(&my_address); npdu_encode_npdu_data(&npdu_data, false, MESSAGE_PRIORITY_NORMAL); pdu_len = npdu_encode_pdu(&Handler_Transmit_Buffer[0], src, &my_address, &npdu_data); if (service_data->segmented_message) { len = abort_encode_apdu(&Handler_Transmit_Buffer[pdu_len], service_data->invoke_id, ABORT_REASON_SEGMENTATION_NOT_SUPPORTED, true); #if PRINT_ENABLED fprintf(stderr,"CPT: Segmented Message. Sending Abort!\n"); #endif goto CPT_ABORT; } len = ptransfer_decode_service_request(service_request, service_len, &data); /* bad decoding - send an abort */ if (len < 0) { len = abort_encode_apdu(&Handler_Transmit_Buffer[pdu_len], service_data->invoke_id, ABORT_REASON_OTHER, true); #if PRINT_ENABLED fprintf(stderr,"CPT: Bad Encoding. Sending Abort!\n"); #endif goto CPT_ABORT; } // Simple example with service number of 0 for read block and 1 for write block // We also only support our own vendor ID. In theory we could support others // for compatability purposes but these interfaces are rarely documented... if((data.vendorID == BACNET_VENDOR_ID) && (data.serviceNumber <= MY_SVC_WRITE)){ // We only try to understand our own IDs and service numbers ProcessPT(&data); // Will either return a result block or an app level status block if(data.serviceParametersLen == 0){ // No respopnse means fatal error error = true; error_class = ERROR_CLASS_SERVICES; error_code = ERROR_CODE_OTHER; #if PRINT_ENABLED fprintf(stderr,"CPT: Error servicing request!\n"); #endif } len = ptransfer_ack_encode_apdu(&Handler_Transmit_Buffer[pdu_len], service_data->invoke_id, &data); } else // Not our vendor ID or bad service parameter { error = true; error_class = ERROR_CLASS_SERVICES; error_code = ERROR_CODE_OPTIONAL_FUNCTIONALITY_NOT_SUPPORTED; #if PRINT_ENABLED fprintf(stderr,"CPT: Not our Vendor ID or invalid service code!\n"); #endif } if (error){ len = ptransfer_error_encode_apdu(&Handler_Transmit_Buffer[pdu_len], service_data->invoke_id, error_class, error_code, &data); } CPT_ABORT: pdu_len += len; bytes_sent = datalink_send_pdu(src, &npdu_data, &Handler_Transmit_Buffer[0], pdu_len); #if PRINT_ENABLED if (bytes_sent <= 0) { fprintf(stderr,"Failed to send PDU (%s)!\n", strerror(errno)); } #endif return; }