# Feature configuration options for BACnet-Stack # Copyright (c) 2020 Legrand North America, LLC. # SPDX-License-Identifier: MIT menuconfig BACNETSTACK bool "BACnet-Stack Support" select REQUIRES_FULL_LIBC help This option enables the BACnet-Stack BACnet library. if BACNETSTACK module = BACNETSTACK module-str = Log level for BACnet module-help = Enable BACnet library to output debug messages source "$(ZEPHYR_BASE)/subsys/logging/Kconfig.template.log_config" config BACNET_VENDOR_NAME string "BACnet Vendor Name" default "BACnet Stack at SourceForge" help BACnet Vendor Name string config BACNET_VENDOR_IDENTIFIER int "BACnet Vendor Identifier" default 260 help BACnet Vendir Identifier config BACNET_PROTOCOL_REVISION int "BACnet Stack protocol-revision number" default 24 help BACnet Stack protocol-revision number config BAC_ROUTING bool "BACnet Routing" help Enable BACnet routing config BACNET_PROPERTY_LISTS bool "BACnet Property Lists" help Enable BACnet Property Lists config BACNET_PROPERTY_ARRAY_LISTS bool "BACnetARRAY Property Lists" help Enable BACnetARRAY Property Lists config BACDL_ETHERNET bool "BACnet Ethernet datalink" help Enable BACnet Ethernet datalink config BACDL_MSTP bool "BACnet MSTP datalink" help Enable BACnet MSTP datalink config BACDL_ARCNET bool "BACnet ARCNET datalink" help Enable BACnet ARCNET datalink config BACDL_BIP bool "BACnet BIP datalink" help Enable BACnet BIP datalink config BACDL_NONE bool "BACnet without datalink" help Enable BACnet without datalink config BACAPP_PRINT_ENABLED bool "BACnet app print" help Enable BACnet app print config BACAPP_SNPRINTF_ENABLED bool "BACnet app snprintf" help Enable BACnet app snprintf config BACDL_BIP_PORT int "BACnet IPv4 UDP port" default 47808 depends on BACDL_BIP help UDP port to listen on (default=47808) config MAX_BBMD_ENTRIES int "Maximum number of Broadcast Device Table entries" default 5 depends on BACDL_BIP help Maximum number of Broadcast Device Table entries config MAX_FD_ENTRIES int "Maximum number of Foreign Device Table entries" default 5 depends on BACDL_BIP help Maximum number of Foreign Device Table entries config BACDL_BIP_ADDRESS_INDEX int "Address index" depends on BACDL_BIP default 0 help Select IPv4 address config BACDL_BIP6 bool "BACnet BIP6" help Enable BACnet BIP6 config BACDL_BIP6_ADDRESS_INDEX int "Unicast address index" depends on BACDL_BIP6 default 0 help Select IPv6 unicast address config BACDL_BIP6_MCAST_ADDRESS string "IPv6 multicast destination" default "FF0E::BAC0" depends on BACDL_BIP6 help IPv6 multicast group address for BACNET. config BACDL_BIP6_PORT int "BACnet IPv6 UDP port" default 47808 depends on BACDL_BIP6 help UDP port to listen on (default=47808) config BACNET_MAX_TSM_TRANSACTIONS int "Number of initiated confirmed-message transactions" default 1 help Number of initiated confirmed-message transactions config BACNET_MAX_ADDRESS_CACHE int "Number of address entries for I-Am bindings" default 1 help Number of address entries for I-Am bindings config BACNET_MAX_CHARACTER_STRING_BYTES int "Maximum number of bytes in a BACnet character string" default 64 help Maximum number of bytes in a BACnet character string config BACNET_MAX_OCTET_STRING_BYTES int "Maximum number of bytes in a BACnet octet string" default 64 help Maximum number of bytes in a BACnet octet string config BACNET_ADDRESS_CACHE_FILE bool "BACnet Address Cache file functionality" help BACnet Address Cache file functionality config BACNET_USE_SECTION_ITERABLE_OBJECT_TABLE bool "Use the Section Iterable for the Object Table" default true help Use the Section Iterable for the Object Table config BACNET_BASIC_OBJECTS_ACCESS bool "Use the BACnet basic access control objects" default false help Use the BACnet basic access control objects config BACNET_BASIC_OBJECT_ACCUMULATOR bool "Use the BACnet basic accumulator object" default false help Use the BACnet basic accumulator object config BACNET_BASIC_OBJECT_ANALOG_INPUT bool "Use the BACnet basic analog input object" default false help Use the BACnet basic analog input object config BACNET_BASIC_OBJECT_ANALOG_OUTPUT bool "Use the BACnet basic analog output object" default false help Use the BACnet basic analog output object config BACNET_BASIC_OBJECT_ANALOG_VALUE bool "Use the BACnet basic analog value object" default false help Use the BACnet basic analog value object config BACNET_BASIC_OBJECT_FILE bool "Use the BACnet basic file object" default false help Use the BACnet basic file object config BACNET_BASIC_OBJECT_BINARY_INPUT bool "Use the BACnet basic binary input object" default false help Use the BACnet basic binary input object config BACNET_BASIC_OBJECT_BINARY_OUTPUT bool "Use the BACnet basic binary output object" default false help Use the BACnet basic binary output object config BACNET_BASIC_OBJECT_BINARY_VALUE bool "Use the BACnet basic binary value object" default false help Use the BACnet basic binary value object config BACNET_BASIC_OBJECT_CALENDAR bool "Use the BACnet basic calendar object" default false help Use the BACnet basic calendar object config BACNET_BASIC_OBJECT_CHANNEL bool "Use the BACnet basic channel object" default false help Use the BACnet basic channel object config BACNET_BASIC_OBJECT_COMMAND bool "Use the BACnet basic command object" default false help Use the BACnet basic command object config BACNET_BASIC_OBJECT_COLOR bool "Use the BACnet basic color object" default false help Use the BACnet basic color object config BACNET_BASIC_OBJECT_COLOR_TEMPERATURE bool "Use the BACnet basic color temperature object" default false help Use the BACnet basic color temperature object config BACNET_BASIC_OBJECT_CHARACTERSTRING_VALUE bool "Use the BACnet basic character-string value object" default false help Use the BACnet basic character-string value object config BACNET_BASIC_OBJECT_DEVICE_SERVER bool "Use the BACnet basic device-server object" default false help Use the BACnet basic device-server object config BACNET_BASIC_OBJECT_DEVICE_CLIENT bool "Use the BACnet basic device-client object" default false help Use the BACnet basic device-client object config BACNET_BASIC_OBJECT_INTEGER_VALUE bool "Use the BACnet basic integer value object" default false help Use the BACnet basic integer value object config BACNET_BASIC_OBJECT_LOAD_CONTROL bool "Use the BACnet basic load control object" default false help Use the BACnet basic load control object config BACNET_BASIC_OBJECT_LIGHTING_OUTPUT bool "Use the BACnet basic lighting output object" default false help Use the BACnet basic lighting output object config BACNET_BASIC_OBJECT_LIFE_SAFETY_POINT bool "Use the BACnet basic life-safety point object" default false help Use the BACnet basic life-safety point object config BACNET_BASIC_OBJECT_MULTISTATE_INPUT bool "Use the BACnet basic multistate input object" default false help Use the BACnet basic multistate input object config BACNET_BASIC_OBJECT_MULTISTATE_OUTPUT bool "Use the BACnet basic multistate output object" default false help Use the BACnet basic multistate output object config BACNET_BASIC_OBJECT_MULTISTATE_VALUE bool "Use the BACnet basic multistate value object" default false help Use the BACnet basic multistate value object config BACNET_BASIC_OBJECT_NOTIFICATION_CLASS bool "Use the BACnet basic notification class object" default false help Use the BACnet basic notification class object config BACNET_BASIC_OBJECT_NETWORK_PORT bool "Use the BACnet basic network port object" default false help Use the BACnet basic network port object config BACNET_BASIC_OBJECT_OCTET_STRING_VALUE bool "Use the BACnet basic octet-string value object" default false help Use the BACnet basic octet-string value object config BACNET_BASIC_OBJECT_POSITIVE_INTEGER_VALUE bool "Use the BACnet basic positive-integer value object" default false help Use the BACnet basic positive-integer value object config BACNET_BASIC_OBJECT_SCHEDULE bool "Use the BACnet basic schedule object" default false help Use the BACnet basic schedule object config BACNET_BASIC_OBJECT_STRUCTURED_VIEW bool "Use the BACnet basic structured view object" default false help Use the BACnet basic structured view object config BACNET_BASIC_OBJECT_TIME_VALUE bool "Use the BACnet basic time value object" default false help Use the BACnet basic time value object config BACNET_BASIC_OBJECT_TRENDLOG bool "Use the BACnet basic trendlog object" default false help Use the BACnet basic trendlog object rsource "subsys/Kconfig" endif # BACNETSTACK