Updated demo objects in ports to use new named constants for error return values.
This commit is contained in:
@@ -200,14 +200,14 @@ int Analog_Input_Read_Property(
|
||||
default:
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
/* only array properties can have array options */
|
||||
if ((apdu_len >= 0) && (rpdata->array_index != BACNET_ARRAY_ALL)) {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
|
||||
return apdu_len;
|
||||
|
||||
@@ -271,7 +271,7 @@ int Analog_Value_Read_Property(
|
||||
else {
|
||||
rpdata->error_class = ERROR_CLASS_SERVICES;
|
||||
rpdata->error_code = ERROR_CODE_NO_SPACE_FOR_OBJECT;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
}
|
||||
@@ -291,7 +291,7 @@ int Analog_Value_Read_Property(
|
||||
} else {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_INVALID_ARRAY_INDEX;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
}
|
||||
|
||||
@@ -304,7 +304,7 @@ int Analog_Value_Read_Property(
|
||||
default:
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
/* only array properties can have array options */
|
||||
@@ -315,7 +315,7 @@ int Analog_Value_Read_Property(
|
||||
(rpdata->array_index != BACNET_ARRAY_ALL)) {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
|
||||
return apdu_len;
|
||||
@@ -361,8 +361,8 @@ bool Analog_Value_Write_Property(
|
||||
Present_Value[object_index] = level;
|
||||
/* Note: you could set the physical output here if we
|
||||
are the highest priority.
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
main loop (i.e. check out of service before changing output) */
|
||||
status = true;
|
||||
} else if (priority == 6) {
|
||||
@@ -387,8 +387,8 @@ bool Analog_Value_Write_Property(
|
||||
/* Note: you could set the physical output here to the next
|
||||
highest priority, or to the relinquish default if no
|
||||
priorities are set.
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
main loop (i.e. check out of service before changing output) */
|
||||
status = true;
|
||||
} else {
|
||||
|
||||
@@ -219,14 +219,14 @@ int Binary_Input_Read_Property(
|
||||
default:
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
/* only array properties can have array options */
|
||||
if ((apdu_len >= 0) && (rpdata->array_index != BACNET_ARRAY_ALL)) {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
|
||||
return apdu_len;
|
||||
|
||||
@@ -217,14 +217,14 @@ int Binary_Value_Read_Property(
|
||||
default:
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
/* only array properties can have array options */
|
||||
if ((apdu_len >= 0) && (rpdata->array_index != BACNET_ARRAY_ALL)) {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
|
||||
return apdu_len;
|
||||
@@ -272,7 +272,7 @@ bool Binary_Value_Write_Property(
|
||||
Present_Value[object_index] = level;
|
||||
/* Note: you could set the physical output here if we
|
||||
are the highest priority.
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. */
|
||||
status = true;
|
||||
} else if (priority == 6) {
|
||||
|
||||
@@ -152,7 +152,7 @@ void Device_Property_Lists(
|
||||
int Device_Read_Property(
|
||||
BACNET_READ_PROPERTY_DATA * rpdata)
|
||||
{
|
||||
int apdu_len = -1;
|
||||
int apdu_len = BACNET_STATUS_ERROR;
|
||||
unsigned index = 0;
|
||||
struct object_functions *pObject = NULL;
|
||||
bool found = false;
|
||||
@@ -705,14 +705,14 @@ int Device_Read_Property_Local(
|
||||
rpdata->error_class = ERROR_CLASS_SERVICES;
|
||||
rpdata->error_code =
|
||||
ERROR_CODE_NO_SPACE_FOR_OBJECT;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
} else {
|
||||
/* error: internal error? */
|
||||
rpdata->error_class = ERROR_CLASS_SERVICES;
|
||||
rpdata->error_code = ERROR_CODE_OTHER;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
}
|
||||
@@ -725,7 +725,7 @@ int Device_Read_Property_Local(
|
||||
else {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_INVALID_ARRAY_INDEX;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
}
|
||||
break;
|
||||
@@ -792,7 +792,7 @@ int Device_Read_Property_Local(
|
||||
default:
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
break;
|
||||
}
|
||||
/* only array properties can have array options */
|
||||
@@ -800,7 +800,7 @@ int Device_Read_Property_Local(
|
||||
(rpdata->array_index != BACNET_ARRAY_ALL)) {
|
||||
rpdata->error_class = ERROR_CLASS_PROPERTY;
|
||||
rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY;
|
||||
apdu_len = -1;
|
||||
apdu_len = BACNET_STATUS_ERROR;
|
||||
}
|
||||
|
||||
return apdu_len;
|
||||
|
||||