Integrated ReadPropertyMultiple with the demo/server application. Compiles, but untested.
This commit is contained in:
@@ -52,6 +52,48 @@ static uint8_t
|
||||
/* without changing the physical output */
|
||||
static bool Multistate_Output_Out_Of_Service[MAX_MULTISTATE_OUTPUTS];
|
||||
|
||||
/* These three arrays are used by the ReadPropertyMultiple handler */
|
||||
static const int Multistate_Output_Properties_Required[] =
|
||||
{
|
||||
PROP_OBJECT_IDENTIFIER,
|
||||
PROP_OBJECT_NAME,
|
||||
PROP_OBJECT_TYPE,
|
||||
PROP_PRESENT_VALUE,
|
||||
PROP_STATUS_FLAGS,
|
||||
PROP_EVENT_STATE,
|
||||
PROP_OUT_OF_SERVICE,
|
||||
PROP_NUMBER_OF_STATES,
|
||||
PROP_PRIORITY_ARRAY,
|
||||
PROP_RELINQUISH_DEFAULT,
|
||||
-1
|
||||
};
|
||||
|
||||
static const int Multistate_Output_Properties_Optional[] =
|
||||
{
|
||||
PROP_DESCRIPTION,
|
||||
-1
|
||||
};
|
||||
|
||||
static const int Multistate_Output_Properties_Proprietary[] =
|
||||
{
|
||||
-1
|
||||
};
|
||||
|
||||
void Multistate_Output_Property_Lists(
|
||||
const int **pRequired,
|
||||
const int **pOptional,
|
||||
const int **pProprietary)
|
||||
{
|
||||
if (*pRequired)
|
||||
*pRequired = Multistate_Output_Properties_Required;
|
||||
if (*pOptional)
|
||||
*pOptional = Multistate_Output_Properties_Optional;
|
||||
if (*pProprietary)
|
||||
*pProprietary = Multistate_Output_Properties_Proprietary;
|
||||
|
||||
return;
|
||||
}
|
||||
|
||||
void Multistate_Output_Init(void)
|
||||
{
|
||||
unsigned i, j;
|
||||
@@ -315,8 +357,8 @@ bool Multistate_Output_Write_Property(BACNET_WRITE_PROPERTY_DATA * wp_data,
|
||||
(uint8_t) level;
|
||||
/* Note: you could set the physical output here if we
|
||||
are the highest priority.
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
main loop (i.e. check out of service before changing output) */
|
||||
status = true;
|
||||
} else if (priority == 6) {
|
||||
@@ -342,8 +384,8 @@ bool Multistate_Output_Write_Property(BACNET_WRITE_PROPERTY_DATA * wp_data,
|
||||
/* Note: you could set the physical output here to the next
|
||||
highest priority, or to the relinquish default if no
|
||||
priorities are set.
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
However, if Out of Service is TRUE, then don't set the
|
||||
physical output. This comment may apply to the
|
||||
main loop (i.e. check out of service before changing output) */
|
||||
status = true;
|
||||
} else {
|
||||
|
||||
Reference in New Issue